ADR 0022: Accessibility, first pass: named controls, panel focus, high contrast, scale
- Status: accepted (2026-11-09)
- Relates to: requirements › Accessibility, roadmap M8, ADR 0005 (typography), ADR 0006
(platforms), ADR 0008 (visual language, focus ring);
docs/accessibility.mdis the user guide
Context
The requirement reads: "Keyboard reachable commands, scalable UI, high-contrast theme, screen-reader labels via AccessKit." Commands were already keyboard reachable (registry shortcuts, the command palette, the shortcut editor). The rest was not there:
- eframe already built with its
accesskitfeature, so Narrator, VoiceOver and Orca saw the window, but most of the shell is custom-painted (tools, layer rows and toggles, timeline icon buttons, Library rows, the stage, the Motion Editor). Those reached assistive technology as anonymous nodes with no role. Number fields, colour wells and menus had a value but no name. - There was no way to move the keyboard between panels, and any focused widget silenced every shortcut, so Tab-ing to a button turned off V, P, F6 and the rest.
theme::Twas aconst: the palette could not change at run time.- The interface scale existed (75–200 %) but at 200 % on a laptop the tools column was cut off, the timeline header clipped its buttons, the status message ran under the readouts, and the stage stayed at the zoom it had before the scale changed.
- Two default-theme pairs missed WCAG AA: white frame numbers on the red playhead (3.3:1) and the accent-blue current-frame number (3.2:1).
Decisions
- Every interactive node has a name and a role, enforced by a test.
src/a11y.rsholds the helpers:controlgives a custom-painted control its role, name and on/off state and draws its focus ring;Named::namednames a value-only widget ("Position X", "Fill colour");sliderpairs a slider with a named number field (egui's own field beside a slider is anonymous unless the slider shows a visible text label);surfacemarks the stage and the Motion Editor graph as canvases;name_title_barandname_splittername the parts egui leaves anonymous. The testa11y::tests::every_interactive_node_has_a_name_and_a_roleruns the whole app on a headlessegui::Contextwith AccessKit on, in 23 states (default, every tool's options, a selection, a movie clip with all four filters, the Motion Editor, a sound keyframe, every dialog, high contrast at 200 %), and fails on any focusable or clickable node without a name or with an unknown role. egui's scroll-area bars are the only exemption. - Names say what and how. An icon-only control's name is its tooltip's first line with the
key in effect (
Pen tool (P),Next frame (.)), read from the keymap so a rebinding shows. Toggles are buttons with a toggled state (Onion skin,Show Ball). Repeated controls carry their row (Lock Hills,Drop Shadow blur X,Restore Untitled). - Ctrl+F6 / Ctrl+Shift+F6 move keyboard focus between panels: Stage, Timeline, Properties, Library, Tools, wrapping. F6 alone stays Insert Keyframe, as animators expect; Ctrl+F6 is the next-pane key of Windows applications, and on macOS our Ctrl is ⌘, so ⌘F6 does not collide with the system's Control-F-key focus shortcuts. Both are view actions in the keymap (rebindable, listed in the shortcut sheet under View) and work even from a text field. Each panel registers one anchor per frame (the stage canvas, the active layer row or the Motion Editor tab, the Properties and Library headers, the active tool); an anchor not drawn this frame is skipped.
- Who owns the keyboard (
a11y::keyboard): nothing focused, or the stage or timeline anchor focused, gets every shortcut, Enter (play) and the arrows (nudge); a focused control (button, checkbox, menu, section header) keeps Enter, Space and the arrows for itself but the other shortcuts still work; a text field keeps every key. Before, any focus disabled all shortcuts. - Pointer-only surfaces are not Tab stops. The frame ruler, each layer's frame grid, the
timeline scroll bar and the Motion Editor graph sense clicks and drags but are not focusable
(
a11y::pointer_only); their keyboard routes are,.Home End F5 F6 F7, Shift+wheel and the Motion Editor's property list. They are still named, so a screen reader can find and click them. - The palette is chosen at run time.
Tis now a zero-sized handle that dereferences to the activeTokens(an atomic selectsGRAPHITEorHIGH_CONTRAST), so everyT.panelcall site stays as it was and a theme change shows in the same frame.theme::apply_paletterestyles egui's own widgets. Rejected: passing the palette through everyUi(hundreds of signatures for no gain: one window, one look), and eguiVisualsalone (it does not reach our custom painting). Contrast tests check the constant palettes directly, so tests running in parallel never depend on the global. - High contrast is built from the same roles, not a second set of colours in the code:
black surfaces, white text (every text role ≥ 7:1, AAA), yellow for focus, selection, the
active tool and accent text, outlined buttons and fields (
control_outline), brighter timeline blocks with black marks, a deep-blue stage selection that shows on white artwork. New tokens make the roles explicit where the old code assumed white:on_active,icon_hot,on_fill,accent_text.guidelines_testschecks every pair a palette draws together (text 4.5:1 or more, UI parts and focus 3:1) for both palettes. - The two AA misses in the graphite theme are fixed without changing its character: the
playhead's frame number is drawn in
ink(5.9:1 on the red flag), accent-coloured text usesaccent_text(a lighter cobalt, 5.7:1), andtext_faintis a step lighter (4.5:1 on raised surfaces too). - Interface scale 75–200 % holds up. The stage stays fitted when its canvas changes size (while nobody has zoomed or panned since the fit), docks start proportional to the window and are capped so the stage keeps room, the tools column scrolls, the timeline header scrolls sideways instead of clipping, and the status message truncates before the readouts (render and cache diagnostics drop out when narrow). The status message is a polite live region, so screen readers announce what an action did.
Consequences
- A new control without a name fails
cargo test, with its role, position and value in the message. New custom-painted controls go througha11y::control. - Single-letter shortcuts now work while a button or checkbox has keyboard focus. Text fields are unaffected.
anicraft --theme high-contrast --scale 200previews either for one run (screenshots, checks) without saving preferences.- Not in this slice (
docs/accessibility.md› Known gaps): elements on the stage and single frames are not exposed one by one; the OS high-contrast setting is not followed automatically; manual passes with Narrator, VoiceOver and Orca are still to do on each platform.